Ethylene oxide as an occupational contact allergen - An underestimated problem? [Ethylenoxid als berufliches kontaktallergen - Ein unterschätztes problem?]

Autor(en): Breuer, K.
Worm, M.
Skudlik, C. 
John, S.M. 
Stichwörter: epichlorohydrin, 106-89-8; ethylene oxide, 16002-48-5, 32587-16-9, 36376-18-8, 75-21-8; article; clinical article; Contact allergy; controlled study; cross allergy; Epichlorohydrin; Ethylene oxide; ethylene oxide, adult; female; human; iatrogenic disease; Irritant contact dermatitis; male; nurse; occupational allergy; Occupational contact dermatitis; Patch test; protective clothing; skin allergy; wrist
Erscheinungsdatum: 2010
Herausgeber: Dustri-Verlag Dr. Karl Feistle
Journal: Allergologie
Volumen: 33
Ausgabe: 8
Startseite: 331
Seitenende: 336
Zusammenfassung: 
Background: Ethylene oxide (EtO) is a volatile epoxy compound which is used to sterilize medical devices. EtO may cause irritant contact dermatitis, but only few cases of allergic contact dermatitis have been reported yet. Objectives: About 20 employees of a department for surgery developed eczematous skin reactions at the contact areas to wrist bands of surgical gowns which had been sterilized with EtO. Patch tests were performed to exclude contact allergy. Methods: Due to the volatility of EtO, patch tests were done with epichlorohydrin (0.1% pet., 1% pet.) which is an epoxy compound chemically related to EtO. Results: 7/8 patients and 4 healthy control persons showed non-allergic irritant reactions to 1.0% epichlorohydrin. 1.0% epichlorohydrin may have induced an iatrogenic sensitization in one of the control persons. None of the control persons reacted to 0.1% epichlorohydrin. Allergic contact dermatitis to EtO and a cross sensitization to epichlorohydrin was diagnosed in a nurse who showed an allergic crescendo patch test reaction to 0.1% epichlorohydrin. Conclusions: EtO can act as an occupational contact allergen in health personnel, a problem that may have been underestimated in the past due to methodological difficulties in patch testing. When allergic contact dermatitis to EtO is suspected, a patch test to 0.1% epichlorohydrin should be performed. © 2010 Dustri-Verlag Dr. Karl Feistle.
ISSN: 03445062
DOI: 10.5414/alp33331
Externe URL: https://www.scopus.com/inward/record.uri?eid=2-s2.0-77957676297&doi=10.5414%2falp33331&partnerID=40&md5=634f40612afae13f1843edb684d856ec

Zur Langanzeige

Seitenaufrufe

8
Letzte Woche
0
Letzter Monat
5
geprüft am 17.05.2024

Google ScholarTM

Prüfen

Altmetric