Liquid density response of a quartz crystal microbalance modified with mesoporous titanium dioxide

DC ElementWertSprache
dc.contributor.authorSchon, P
dc.contributor.authorMichalek, R
dc.contributor.authorWalder, L
dc.date.accessioned2021-12-23T15:56:59Z-
dc.date.available2021-12-23T15:56:59Z-
dc.date.issued1999
dc.identifier.issn00032700
dc.identifier.urihttps://osnascholar.ub.uni-osnabrueck.de/handle/unios/2649-
dc.description.abstractA new method for the determination of liquid densities with a surface-modified 5-MHz quartz crystal microbalance (QCM) is described. Modifier is a thin mesoporous TiO2 him coated on the crystal of the QCM (50 < porosity (P) < 70%; 0.1 < film thickness (d(T)) < 6.0 pm). Modification is accompanied by a resonant frequency shift (1 < Delta f(T) < 60 kHz) reflecting the TiO2 film thickness (d(T)), its porosity (P), and the density of the nanocrystals (rho(T)). Immersion of the QCM in a liquid of density rho(1) leads to a further resonant frequency shift (Delta f(1)) of 0.8-40 Wt depending mainly on d(T), P, and rho(1). The liquid in the pores behaves as a rigid mass. In the case of thick films, the contribution from the bulk of the film to Delta f(1) is so important that surface phenomena related to the viscosity of the solvent and to the roughness of the film/liquid interface become negligible; i.e., a crystal with a 6-mu m TiO2 film can be used to measure the density of a liquid of unknown viscosity with an average error of /-0.02 g/cm(3). Model considerations lead to the differential d Delta f(1)/d Delta f(T) = rho(1)P/rho(T)(100 - P); i.e., the accurate solvent density becomes available from Delta f(1) differentiated with respect to Delta f(T) without any interference from viscosity and surface roughness. Experimentally, an average error of /-0.005 g/cm(3) was observed. Scope and limits of the new technique are presented.
dc.language.isoen
dc.publisherAMER CHEMICAL SOC
dc.relation.ispartofANALYTICAL CHEMISTRY
dc.subjectChemistry
dc.subjectChemistry, Analytical
dc.subjectELECTRODES
dc.subjectGOLD
dc.subjectMORPHOLOGY
dc.subjectSENSOR
dc.subjectSOLVENT-VAPOR
dc.subjectSURFACE-ROUGHNESS
dc.subjectTHIN-FILMS
dc.titleLiquid density response of a quartz crystal microbalance modified with mesoporous titanium dioxide
dc.typejournal article
dc.identifier.doi10.1021/ac9903813
dc.identifier.isiISI:000082075100001
dc.description.volume71
dc.description.issue16
dc.description.startpage3305
dc.description.endpage3310
dc.contributor.orcid0000-0002-5497-034X
dc.publisher.place1155 16TH ST, NW, WASHINGTON, DC 20036 USA
dcterms.isPartOf.abbreviationAnal. Chem.
crisitem.author.deptInstitut für Chemie neuer Materialien-
crisitem.author.deptidinstitute11-
crisitem.author.orcid0000-0002-5497-034X-
crisitem.author.parentorgFB 05 - Biologie/Chemie-
crisitem.author.grandparentorgUniversität Osnabrück-
crisitem.author.netidWaLo966-
Zur Kurzanzeige

Seitenaufrufe

4
Letzte Woche
0
Letzter Monat
1
geprüft am 01.06.2024

Google ScholarTM

Prüfen

Altmetric