An attempt to improve diagnostics of contact allergy due to epoxy resin systems. First results of the multicentre study EPOX 2002

DC ElementWertSprache
dc.contributor.authorGeier, Johannes
dc.contributor.authorLessmann, Holger
dc.contributor.authorHillen, Uwe
dc.contributor.authorJappe, Uta
dc.contributor.authorDickel, Heinrich
dc.contributor.authorKoch, Patrick
dc.contributor.authorFrosch, Peter J.
dc.contributor.authorSchnuch, Axel
dc.contributor.authorUter, Wolfgang
dc.date.accessioned2023-01-11T08:17:02Z-
dc.date.available2023-01-11T08:17:02Z-
dc.date.issued2004
dc.identifier.issn0105-1873
dc.identifier.urihttp://osnascholar.ub.uni-osnabrueck.de/handle/unios/65220-
dc.description.abstractEpoxy resin systems (ERSs) are a frequent cause of occupational allergic contact dermatitis. Sensitization occurs not only to the resins, but also to hardeners and reactive diluents. However, only a fraction of the ERS components currently in use are available for patch testing. With the multicentre study EPOX 2002, we attempted to improve diagnostics in this field by patch testing with components currently used in ERSs. During the first study period (October 2002 to July 2003), in addition to commercially available ERS patch test substances, 16 study substances (1 resin, 9 hardeners and 6 reactive diluents) were patch tested in 70 patients with suspected contact allergy due to ERSs and 22 patients with a prior positive patch test reaction to epoxy resin (ER) in the standard series. Most frequently, allergic reactions to ER based on diglycidyl ether of bisphenol A and F were observed (55.2% and 43.7%, respectively). Agreement between positive reactions to both resins, which can be explained by immunological cross-sensitization and/or coexposure, was substantial [Cohen's kappa 0.65 (95% CI: 0.49-0.80)]. Among the reactive diluents, 1,6-hexanediol diglycidyl ether (1,6-HDDGE) and 1,4-butanediol diglycidyl ether (1,4-BDDGE) were the most frequent allergens, with 19.5% and 18.4% positive reactions, respectively. Although agreement between positive reactions to 1,6-HDDGE and 1,4-BDDGE was even better than with the 2 resins, the sample size is considered too small to decide reliably whether 1,6-HDDGE alone could serve as a marker allergen for both. Allergic reactions to p-tert-butylphenyl glycidyl ether and to phenyl glycidyl ether (PGE) occurred in 11.5% of the patients tested, with only moderate agreement. All patients positive to cresyl glycidyl ether (6.8%) also reacted to PGE. Of the hardeners tested, m-xylylene diamine was the most frequent allergen (13.8%), followed by isophorone diamine (5.7%). No reactions were observed to several substances, the test concentration of which may have been too low and will be increased in the future.
dc.language.isoen
dc.relation.ispartofContact dermatitis
dc.sourcePubMed
dc.titleAn attempt to improve diagnostics of contact allergy due to epoxy resin systems. First results of the multicentre study EPOX 2002
dc.typejournal article
dc.identifier.doi10.1111/j.0105-1873.2004.00465.x
dc.identifier.pmid15606651
dc.contributor.affiliationInformation Network of Departments of Dermatology (IVDK), University of Göttingen, 37075 Göttingen, Germany. jgeier@ivdk.org
dc.description.volume51
dc.description.issue5-6
dc.description.startpage263
dc.description.endpage272
local.import.remainsU3 : Clinical Trial Journal Article Multicenter Study Research Support, Non-U.S. Gov't
local.import.sourcefileDickel_Heinrich_sk_Citavi_20230109.ris
crisitem.author.deptUniversität Osnabrück-
Zur Kurzanzeige

Seitenaufrufe

16
Letzte Woche
0
Letzter Monat
0
geprüft am 19.04.2024

Google ScholarTM

Prüfen

Altmetric